New

Accessories
Digital flow switch - FC series

Flow range: 0.5~1000 L/min, Linearity: ±3%F.S.(output port), Pressure characteristics: ±5% F.S., Temp. characteristics: ±0.2% F.S./℃(15~35℃, baseline 25℃)

  • Flow rate management:

    Flow rate management and accumulation.
  • High recognition:

    Dual screen and 2 color display.
Power 24V Current consumption 50mA or less
Response time 50ms or less Min. operating pressure -0.09MPa
Max. operating pressure 0.7MPa Proof pressure 1MPa
Operating temp. and humidity 0~50℃, 90%RH Operating fluid temperature 0~50℃
Linearity ±3%F.S. below(Output port) Pressure characteristics ±5%F.S.
Temp. characteristics ±0.2% F.S./℃(15~35℃, baseline 25℃) Repeatablity ±1% F.S.
Signal output(analog output) Output voltage: 1~5V
Output current: 4~20mA
Output signal(switch output) 2 NPN open clooector output
2 PNP open clooector output
New

Accessories
Digital separation flow switch - FC-D series

Flow range: 0.5~1000 L/min, Linearity: ±3%F.S.(output port), Pressure characteristics: ±5% F.S., Temp. characteristics: ±0.2% F.S./℃(15~35℃, baseline 25℃)

  • Flow rate management:

    Flow rate management and accumulation.
  • High recognition:

    Dual screen and 2 color display.
  • Data concentrating:

    With separated display panel, data can be managed concentratively.
Power 24V Current consumption 50mA or less
Response time 50ms or less Min. operating pressure -0.09MPa
Max. operating pressure 0.7MPa Proof pressure 1MPa
Operating temp. and humidity 0~50℃, 90%RH Operating fluid temperature 0~50℃
Linearity ±3%F.S. below(Output port) Pressure characteristics ±5%F.S.
Temp. characteristics ±0.2% F.S./℃(15~35℃, baseline 25℃) Repeatablity ±1% F.S.
Signal output(analog output) Output voltage: 1~5V
Output current: 4~20mA
Output signal(switch output) 2 NPN open clooector output
2 PNP open clooector output
New

Accessories
Digital flow adjust switch - FC-R series

Flow range: 0.5~1000 L/min, Linearity: ±3%F.S.(output port), Pressure characteristics: ±5% F.S., Temp. characteristics: ±0.2% F.S./℃(15~35℃, baseline 25℃)

  • Flow rate management:

    Flow rate management and accumulation.
  • High recognition:

    Dual screen and 2 color display.
  • Adjust flow rate quickly:

    With needle vavle, can adjust flow rate quickly in operating .
Power 24V Current consumption 50mA or less
Response time 50ms or less Min. operating pressure -0.09MPa
Max. operating pressure 0.7MPa Proof pressure 1MPa
Operating temp. and humidity 0~50℃, 90%RH Operating fluid temperature 0~50℃
Linearity ±3%F.S. below(Output port) Pressure characteristics ±5%F.S.
Temp. characteristics ±0.2% F.S./℃(15~35℃, baseline 25℃) Repeatablity ±1% F.S.
Signal output(analog output) Output voltage: 1~5V
Output current: 4~20mA
Output signal(switch output) 2 NPN open clooector output
2 PNP open clooector output

Digital flow switch - FC series

2D.3D下載

Digital separation flow switch - FC-D series

2D.3D下載

Digital flow adjust switch - FC-R series

2D.3D下載