Digital Flow Switch
Features of Gas Mass Flow Meter:
- ● Quick response ● High accuracy ● Supports adjustable measurement ranges.
- Detail
- Code of order
| Item | Model | C300 - EtherCAT | C300 - RS-485 | C300 - Profibus DP |
|---|---|---|---|---|
| Measuring range (Nitrogen test results) | 10, 20, 50, 100, 200, 500 (sccm); 1, 2, 5, 10, 20, 50, 100, 200 (slm) | |||
| Air requirements | Clean, dry gases | |||
| Measurable gases | Air、N2、O2、CO2、He、H2、 CH4、Ar、SiH4、NH3、N2O、BCI3、CI2 | |||
| Flow display | Accuracy | ±0.3% F.S. (≤30%F.S. ); ±1.0% S.P. ( > 30%F.S. ) | ||
| Repeatability (F.S.) | ±0.2% F.S. or less | |||
| Resolution | 0.01sccm ≤ 100sccm;1sccm > 100sccm | |||
| Range ratio | 50:1 | |||
| Withstand pressure (bar) | 10 bar | |||
| Leakage rate | Fluororubber sealing : 4×10-10 Pa m3/s He or less; All-metal sealing : 1×10-12 Pa m3/s He or less | |||
| Response time (s) | Flow meter: 10ms or less; Controller: 1s or less | |||
| Startup time (s) | 1s or less | |||
| Environment | Operating temperature (℃) | 0 ~ 50℃(No icing, no frosting) | ||
| Operating humidity (RH) | 10% ~ 90%RH or less | |||
| Operating pressure | Flow meter: 10bar; Controller: Maximum 6 bar (customizable) | |||
| Storage temperature (℃) | -20 ~ 85℃(No icing, no frosting) | |||
| Power | Voltage | DC 24 V (Via Side M8 connector) | DC 24 V (Via Top DB9M connector) | DC 24 V (Via Side M8 connector) |
| Power consumption (W) | 2.7 or less | |||
| Electrical parameters | Top interface type | RJ45 double-mesh(with indicator light) | DB9M | DB9F |
| Side interface type | M8 aviation connector | RJ45 double-mesh(without indicator light) | M8 aviation connector | |
| Communication method | EtherCAT | RS-485, 0 ~ 5 V, 4 ~ 20 mV | Profibus DP | |
| Communication output | Profibus DP | None | None | Communication via top DB9F interface; device address range: 1 (default) to 255, adjustable via top dial; maximum 12M adaptive baud rate |
| EtherCAT | Communication via top RJ45 interface; device address range: 1 (default) to 999, adjustable via upper-level software or command | None | None | |
| RS-485 | None | Communication via top DB9M or side RJ45 interface; supports Modbus-RTU and MKS protocols; device address range: 1 (default) to 99, supports baud rates of 9600, 19200 (default), 38400, and others, adjustable via top dial | Yes | |
| Analog output | 0 ~ 5 V | None | Communication via top DB9M interface (optional while ordering) | None |
| 4 ~ 20 mA | None | Communication via top DB9M interface (optional while ordering) | None | |
| Connector type | No external connector (standard type) ; Compression Fitting: 1/4", 1/2"; VCR1/4", VCR1/2" | |||
| Gas contact material | Fluorosilicone rubber sealing: 316L stainless steel, fluororubber, silicon nitride; all-metal sealing: 316L stainless steel | |||
| Body material | Base:316L Stainless steel ; Outer shell: Aluminum alloy | |||
| Sealing material | FKM fluororubber or all-metal (316L stainless steel) | |||
| Weight (kg) | Flow meter : 0.8; Controller: 0.85 ~ 2.8 | |||