Features of Differential Pressure Flow Sensor:
- 1.Display pressure, airflow, temperature and cumulated airflow simultaneously. 2.Could be used solely, or go with U series modulizedly. 3.CO2 emission monitor meter
- Detail
- Code of order
Applicable models | U200/U300/U400 |
Flow rate(L/min) | 1000/2000/3000 |
Port size | PT1/4、PT3/8、PT1/2 |
Measure fluid | Air, Nitrogen |
Flow direction | one-way |
Flow unit-Display | 2 color LCD |
Flow unit-Displayable range | 0~3000 |
Flow unit-Min. display unit(L/min) | 1 |
Flow unit-Unit | L/min, CFM |
Pressure indication-Rated pressure range(kPa) | 0~800 |
Pressure indication-Displayable range(kPa) | 0~1000 |
Pressure indication-Proof pressure(MPa) | 1.3 |
Pressure indication-Unit | bar、kPa、psi |
indication-Rated temperature range(°C) | -10~60 |
indication-Displayable range(°C) | 0~50 |
indication-Minimum unit(°C) | 1 |
Cumulative flow(CO2 emission monitor meter )-Displayable range | 9999999999L、9999Kg |
Cumulative flow(CO2 emission monitor meter )-Unit | Cumulative flow(L), Carbon emission(Kg) |
Power Type-Voltage | DC24V(±10%) |
Current consumption | 50mA or less |
Response time | 50ms or less |
Accuracy-Flow rate | ±3%F.S. |
Accuracy-Pressure | ±1%F.S. |
Accuracy-Temperature | ±2.5° C |
Accuracy-Repeatability(Pressure/Flow rate) | ±1%F.S. |
Accuracy-Operating temperature range | within±5%F.S./° C (0~50° C、25° C base) |
Accuracy-Operating range | 3 ~ 100%F.S. |
Output type-Analog output | Voltage output: 1 ~ 5V, Load Impedance: 50kΩ |
Output type-Switch output | 1 NPN / 1PNP open collector output |
Wiring | Cable Connector X 5 Core (QD) |
Enclosure | IP65 |
Circuit protection | Reverse power connect protection |
Weight(g) | 240/250 |