Flow rate /L/min | FCSR:0.5/2/10/20 |
Port size/mm | FCSR:Ø4、Ø6 |
Measure fluid | Air, nitrogen |
Flow::Display Displayable range/L/min Min. display unit/L/min | 2 color LCD 0~0.5/0~2/0~10/0~20 0.001/0.01/0.1 |
Accumulated pulse flow function Displayable range Min. display unit | 99999.99/999999.9 0.001/0.01/0.1 |
Power Type : Voltage | DC24V(±10%) |
Current consumption | 50mA or below |
Response time | 50mA or below |
Environment Min. operating pressure Max. operating pressure Proof pressure Ambient of fluid temperature and humidity Operating temperature range | 0.1 0.7 1 0~50℃ , 90%RH or below 0~50℃ |
Accuracy Operating rangeLinearity Pressure characteristics Temperature characteristics Repeatability | 3~100%F.S. within ±3%F.S.(The secondary atmospheric release) within ±5%F.S. within ±0.2%F.S/℃ (15~35℃ , 25℃ base) within ±1%F.S. |
Output type Analog output Switch output | 2NPN open collector output 2PNP open collector output(Max. loading current: 50mA; Power supply voltage: DC24V) |
Wiring | Φ3.8AWG26 X 5 Core |
Enclosure | IP40 |
Circuit protection | Reverse power connect protection, Output reverse connection protection |
Weight /g | 87 |