Flow rate L/min | 0.03 | 0.1 | 0.5 |
Port size | M5 |
Applicable fluid | Air, N2 , O2 , He, H2 , Ar, CO |
Flow unit | Rated flow range L/min | 0~0.03 | 0~0.1 | 0~0.5 |
Detection direction | Unidirection |
Power supply voltage | DC8V ~ 24V |
Current consumption | 20mA or less |
Response time | 5ms |
Environment | Min. operating pressure MPa | 0.001 |
Max. operating pressure MPa | 0.5 |
Proof pressureMPa | 0.7 |
Ambient of fluid temperature and humidity | 0 ~ 50°C, 95%RHor less |
Operating temperature range | 0 ~ 55°C |
Indicator accuracy | Operating range | 3 ~ 100%F.S. |
Linearity | within ±3%F.S. (The secondary atmospheric release) |
Temp. characteristic | within±2%F.S./°C(0 ~ 50°C, base 20°C) |
Pressure characteristic | within±2%F.S.(base 101.325kPa) |
Repeatability | within±0.1%F.S. |
Output signal | Analog output | Voltage output:0.5 ~ 4.5V,Load Impedance:1kΩ |
Digital output | I²C communication |
Environmental resistant | Enclosure | IP40 |
Certification | CE (IEC 61000-2 ; -4),RoHS |
Ambient temp. range | -20~70 |
Thread | M5x0.8P (Tightening torque 1 ~ 1.5 N.m) |
Vibration | Total amplitude 1.5mm or 10G, 10 Hz - 55 Hz - 10 Hz scan for 1 minute, 2 hours each direction of X, Y and Z |
Shock | 100m/s² (10G),3 times each in direction of X, Y and Z |
Lead Wire | Ø3.8AWG28 x 5 Core |
Weight g | 12 |