Measured flow rate range L/min | 0~0.5 | 0~1 | 0~5 | -0.5~0.5 | -1~1 | -5~5 |
Flow direction | Unidirection | Bidirectional |
Measure fluid | Dry air, N₂、Non-corrosive / Non-flammable gas |
Rated pressure range kPa | -100~100 |
Withstand pressure kPa | 300 |
Power supply voltage | 15 ~ 24V DC ±10%, Ripple (P-P) ≤ 10% |
Current consumption | ≤ 30mA |
Flow | Repeatability | ≤ ± 2% F.S. |
Linearity | Non-linearity |
Temp. characteristic | ≤ ± 0.6% F.S./°C | ≤ ± 0.3% F.S./°C |
Pressure characteristic | ± 10% F.S. | ±5% F.S. |
Pressure | Repeatability | ≤ ± 1% F.S. |
Linearity | ± 0.5% F.S. |
Temp. characteristic | ± 2% F.S. |
Response time | Flow | ≤ 5ms (90% response time) |
Pressure | ≤ 1ms |
Switch on indicator | Green/ orange/ red |
Analog Output | Flow | Voltage Output Range: 1~5V ±5% F.S. (±0.2V) (Non-linearity), Output Impedance: 1 KΩ |
Pressure | Voltage Output Range: 1~5V ±1% F.S. (±0.04V) (Linearity), Output Impedance: 1 KΩ |
Environment | Enclosure | IP40 |
Working fluid temp | 0 ~ 50° C (No condensation or freezing) |
Ambient temp. range | Operation : 0 ~ 50° C ; Storage : -10 ~ 60° C (No condensation or freezing) |
Ambient humidity Range | Operation / Storage : 35 ~ 85% R.H. (No condensation) |
Withstand voltage | 1000V AC in 1-min (between case and lead wire) |
Insulation resistance | ≥ 50MΩ (500V DC, between case and lead wire) |
Vibration | Total amplitude 1.5mm or 10G, 10 Hz - 55 Hz - 10 Hz scan for 1 minute, 2 hours each direction of X, Y and Z |
Shock | 100m/s² (10G),3 times each in direction of X, Y and Z |
Lead Wire | Ø2.9 PUR - 28 AWG ( 0.078 mm² ) - 4 cores |
Weight g | Body | Approx. 8.6 g (w/o Port) ; Approx. 12.2 g (M5 Port) |
3 meter lead wire | +34.5 |