FC-D-Separable Numeric Display Flow Switch (Mass Flow Type)

Features of Separable Numeric Display Flow Switch (Mass Flow Type):

  • 1.Horizontal display function.
    2.Detachable display, optimized visibility.
    3.No need for straight pipe.

FC-D-Separable Numeric Display Flow Switch (Mass Flow Type)
  • Detail
  • Code of order
Model FCSD/FCMD/FCHD
Flow rate/L/min FCSD:0.5/2/10/20
FCMD:50/100/200
FCHD:500/1000
Port size/mm FCSD:Ø4、Ø6、Ø8
FCMD:Ø6、Ø8
FCHD:Rc1/2
Measure fluid Air, nitrogen
Flow unit Display:2 color LCD
Displayable range(L/min):0~0.5/0~2/0~10/0~20/0~50/0~100/0~200/0~500/0~1000
Min. display unit(L/min):0.001/0.01/0.1/1
Accumulated
pulse flow
function
Displayable range(L):99999.99/999999.9/999999
Min. display unit(L):0.001/0.01/0.1/1
Power Type Voltage:DC24V(±10%)
Current consumption 50mA or below
Response time 50ms or below
Environment Min. operating pressure(MPa):0.1
Max. operating pressure(MPa):0.7
Proof pressure(MPa):1
Ambient of fluid temperature and
humidity:0~50℃ , 90%RH or below
Operating temperature range:0~50℃
Accuracy Operating range:3~100%F.S.
Linearity:within ±3%F.S.(The secondary atmospheric release)
Pressure characteristics:within ±5%F.S.
Temperature characteristics:within ±0.2%F.S/℃ (15~35℃ , 25℃ base)
Repeatability:within ±1%F.S.
Output
type
Analog output:輸Voltage output: 0.5~4.5V, Load Impedance: 50kΩ
Switch output:2NPN open collector output(Max. loading current: 50mA; Power supply voltage: DC24V)
Switch output:2PNP open collector output(Max. loading current: 50mA; Power supply voltage: DC24V)
Wiring Ø3.8AWG26 X 5 Core
Enclosure IP40
Circuit protection  Reverse power connect protection, Output reverse connection protection
Weight/g 56/141