Flow rate | 50 | 100 |
Port size | Ø8, PT1/4 |
Measure fluid | Air, nitrogen |
Flow unit | Display | 2 color LCD |
Displayable range | 0~50 | 0~100 |
Min. display unit | 0.1 |
Accumulated pulse flow function | Displayable range | 999999.9 |
Min. display unit | 0.1 |
Power Type | Voltage | DC24V(±10%) |
Current consumption | 250mA or less |
Response time | 50ms or less |
Controlled | Operating range | 3~100%F.S. |
Response time | Set within ±5%F.S. within 1 second |
Linearity | within ±3%F.S. |
Repeatability | within ±1%F.S. |
Pressure characteristics | within ±5%F.S. |
Temperature characteristics | within ±2%F.S/℃(15~35℃, 25℃base) |
Environment | Min. operating pressure | 0.1 |
Max. operating pressure | 0.7 |
Proof pressure | 1.0 |
Ambient of fluid temperature and humidity | 0~50℃、90%RH or less |
Operating temperature range | 0~50℃(No condensation) |
Input signal | Analog voltage | 0~5V DC(10kΩ) / 0~10VDC(6.7kΩ) Switchable |
Current voltage | 4~20mADC(250Ω) |
Output signal | VN | Voltage output: 1~5V (Load Impedance: 50kΩ) Error output NPN open collector output (load 50mA or less, voltage drop 2.4V or less) |
VP | Voltage output: 1~5V (Load Impedance: 50kΩ) Error output PNP open collector output (load 50mA or less, voltage drop 2.4V or less) |
NN | Switch output NPN open collector output (load 50mA or less, voltage drop 2.4V or less) Error output NPN open collector output (load 50mA or less, voltage drop 2.4V or less) |
PP | Switch output PNP open collector output (load 50mA or less, voltage drop 2.4V or less) Error output PNP open collector output (load 50mA or less, voltage drop 2.4V or less) |
Wiring | Cable Connector X 5 Core (QD) |
Enclosure | IP40 |
Circuit protection | Reverse power connect protection, Output reverse connection protection |
Weight (G) | 160 |