| Fluid | Air |
| Min. pressure | Set pressure 100 kPa |
| Max. pressure/kPa | 200 | 1000 |
| Pressure range setting | 5-100 | 5-500 | 5-900 |
| Power-Voltage | DC24V±10% |
| Power-Current consumption | Power supply voltage DC24V type:0.12A or less |
| Input signal-Current type | DC4~20mA |
| Input signal-Voltage type | DC0~5V, DC0~10V |
| Input impedance-Current type | about 240Ω |
| Input impedance-Voltage type | about 240Ω |
Output signal (Display output) Analog output | DC 1~5V (Load impedance: 1KΩ or above) Output accuracy within ±6% (F.S.) |
Output signal (Display output) Current type | DC4~20mA |
| Linearity | ±1% or less (F.S.) |
| Hysteresis | ±1% or less (F.S.) |
| Repeatability | ±0.5% or less (F.S.) |
| Sensitivity | 0.2% or less (F.S.) |
| Temperature characteristics | Within ±3%F.S.(The secondary atmospheric release) |
| Output pressure indication-Accuracy | within ±5%F.S. |
| Output pressure indication-Minimum unit | ±0.2%F.S../ °C or less (15~35, base 25) |
| Operating temperature range/°c | 0 ~ 50°(No condensation) |
| Weight/g | 88(Without option) |